YMC series Fan Speed Controller are compact, easy to install and extremely reliable. They have been designed to meet our customers¡¯ requirements, based on comprehensive application experience. More than twelve years of manufacturing experience ensure that our Fan Speed Controller and condensing unit stand out with regards to quality and long life.
SPECIFICATIONS
|
Model
|
|
|
Mains supply voltage |
220V-240V |
|
Mains supply frequency |
50/60HZ |
|
Maximum output voltage |
> 98% of supply voltage |
|
Maximum current |
9A (at maximum voltage output) |
|
Motor numbers |
1-up, subject to Maximum current |
|
Power factor (cos¦× ) motor |
>0.6 |
|
Operation ambient temperature |
-20¡æto60¡æ |
|
Operation /Storage ambient
humidity |
10%to95£¥ |
|
Storage ambient Temp. |
-40¡æto85¡æ |
|
Minimum speed under cooling mode |
adjustable from 10% to 98% of supply voltage |
|
Motor speed at heating mode
for Heat Pump unit |
100% |
|
Material of case/cover |
ABS flame retardant plastics |
|
Water Proof |
No |
|
Shipping weight |
individual pack 200g |
|
Wiring connections |
Screw terminals 1mm2 up to 21/2mm2 |
|
Refrigerant type |
R410A, R22, R407C, R404A |
|
Model
|
|
|
Mains supply voltage |
220V-240V |
|
Mains supply frequency |
50/60HZ |
|
Maximum output voltage |
> 98% of supply voltage |
|
Maximum current |
20A (at maximum voltage output) |
|
Motor numbers |
1-up, subject to Maximum current |
|
Power factor (cos¦× ) motor |
>0.6 |
|
Operation ambient temperature |
-20¡æto60¡æ |
|
Operation /Storage ambient
humidity |
10%to95£¥ |
|
Storage ambient Temp. |
-40¡æto85¡æ |
|
Minimum speed under cooling mode |
adjustable from 10% to 98% of supply voltage |
|
Motor speed at heating mode
for Heat Pump unit |
Not applicable |
|
Material of case/cover |
ABS flame retardant plastics |
|
Water Proof |
No |
|
Shipping weight |
individual pack 320g |
|
Wiring connections |
Screw terminals 1mm2 up to 21/2mm2 |
|
Refrigerant type |
R410A, R22, R407C, R404A |
The performance specifications are nominal and conform to acceptable standards. For applications at conditions beyond these specifications, consult the local office or representative.
|
Model
|
|
|
Mains supply voltage |
220V-240V |
|
Mains supply frequency |
50/60HZ |
|
Maximum output voltage |
> 98% of supply voltage |
|
Maximum current |
9A (at maximum voltage output) |
|
Motor numbers |
1-up, subject to Maximum current |
|
Power factor (cos¦× ) motor |
>0.6 |
|
Operation ambient temperature |
-20¡æto60¡æ |
|
Operation /Storage ambient
humidity |
10%to95£¥ |
|
Storage ambient Temp. |
-40¡æto85¡æ |
|
Minimum speed under cooling mode |
adjustable from 10% to 98% of supply voltage |
|
Motor speed at heating mode
for Heat Pump unit |
Not applicable |
|
Material of case/cover |
ABS flame retardant plastics |
|
Water Proof |
No |
|
Shipping weight |
individual pack 320g |
|
Wiring connections |
Screw terminals 1mm2 up to 21/2mm2 |
|
Refrigerant type |
R410A, R22, R407C, R404A |
|
Model
|
|
|
Mains supply voltage |
220V-240V |
|
Mains supply frequency |
50/60HZ |
|
Maximum output voltage |
> 98% of supply voltage |
|
Maximum current |
20A (at maximum voltage output) |
|
Motor numbers |
1-up, subject to Maximum current |
|
Power factor (cos¦× ) motor |
>0.6 |
|
Operation ambient temperature |
-20¡æto 60¡æ |
|
Operation /Storage ambient
humidity |
10%to95£¥ |
|
Storage ambient Temp. |
-40¡æto85¡æ |
|
Minimum speed under cooling mode |
adjustable from 10% to 98% of supply voltage |
|
Motor speed at heating mode
for Heat Pump unit |
Not applicable |
|
Material of case/cover |
ABS flame retardant plastics |
|
Water Proof |
No |
|
Shipping weight |
individual pack 320g |
|
Wiring connections |
Screw terminals 1mm2 up to 21/2mm2 |
|
Refrigerant type |
R410A, R22, R407C, R404A |
The performance specifications are nominal and conform to acceptable standards. For applications at conditions beyond these specifications, consult the local office or representative.
INTRODUCTION
1.The controllers are designed for speed variation of single phase motors, especially for the fan speed control on air cooled condensers. Monitor the condenser tube temperature, through speed variation of the fan of air-cooled condenser, results in optimum performance.
2.Using a temperature sensor as the input device to the fan speed controller, gives quick response to the pressure variation in the refrigerant system. The controller varies the fan speed under cooling mode from 10% to 98% at linear speed adjustment.Under cooling mode in low ambient, the controller can prevent the fan frequently switch. The linear fan speed control can enhance the efficiency of the compressor, improving the system performance with reducing the power consumption.The controller is programmable with control panel to adjust the temperature setpoint. Upon necessary, can adjust the temperature setpoint to adjust the outdoor fan speed, with lower the outdoor noise.
3.The controller applicable for various refrigerant type condensing units: R410A, R22, R407C, R404A, etc.The controller is programmable. When equipped in different type of condensing unit, the setpoint is adjustable by control panel according to different refrigerant pressure ¨C temp table.
4.For DX air conditioning outdoor condensing units, under cooling model: when condensing coils temperature (pressure) is high, the fan speed controller will speed up the fan motor to reduce the condensing coils temperature (pressure); when condensing temperature (pressure) is low, the controller will lower the fan motor running speed to maintain the condensing temperature (pressure).For DX heat pump unit, under heating mode, the controller will bypass the outdoor motor speed adjustment. Outdoor fan motor running at full speed. (There is connector to import 4-way valve signal.)
5.For refrigeration condensing unit with digital expansion valves, when the ambient temperature is low, the controller will lower the outdoor motor speed to guarantee the expansion valve normal operation, with enough flow rate though the expansion valve supplying evaporator, maintain the demand cold capacity.
|
Feature and Benefits |
|
Condenser pressure control by fan
speed variation |
Optimum condenser pressure control all the
year round.
Less noise during colder (night) period |
|
Condenser coil temp. input. |
Quick response to coil pressure variations.
Easy to install |
|
Transducers with proven reliability. |
More than half a million in use today.
|
|
Programmable setpoint setting. |
Setpoint easy adjustable. For use on various
non-corrosive refrigerants. |
|
Both Cooling only & Heat Pump unit |
With 4-way valve signal input, bypass heating operation |
COIL PRESSURE ¨C TEMP. TABLE
|
Meter Pressure
MPa |
0.7-0.8 |
0.8-0.9 |
1-1.1 |
1.2-1.3 |
1.4-1.5 |
1.6-1.7 |
1.8-1.9 |
2.0-2.1 |
2.2-2.3 |
2.4-2.5 |
|
Temperature ¡æ |
R22 |
15.5 |
19.6 |
27 |
33.4 |
39.1 |
44.3 |
49.1 |
53.4 |
57.5 |
61.4 |
|
R404a |
9.2 |
13.8 |
20.4 |
26.6 |
32.2 |
37.2 |
41.8 |
46.1 |
50.0 |
55.5 |
|
R407c |
13 |
16.9 |
23.8 |
29.8 |
35.3 |
40.1 |
44.6 |
48.8 |
52.7 |
56.4 |
|
R410a |
0 |
4 |
12 |
17 |
21 |
25 |
30 |
35 |
37 |
41 |
USE OF BUTTONS ON CONTROL PANEL
Once installed, press the SET key and then the light of the display will shine. Press the key of ¡üor ¡ý,that will set the requested condensing temperature while the display will show the rate of the fan speed.
The Fan Speed controller of YMC706 series can adjust the fan speed rate to control the condensing temperature under the maximum condensing temperature. At the same time it displays percentage of fan speed rate. When the fan speed control displays (Ò»LO), the fan speed is running at the lowest rate. You can watch the display on the fan speed control to compare with the table 1 to know the fact of condensing temperature.
Note: If the sensor happen fault, the fan speed control will display ¡°EO¡±.